• Nedavno
Protoka vode Prekidač Djelomičan Nerđajućeg Čelika Tip 6-380V 1 Vesla Kontrola Protoka Vode Prekidač 1.0 MPa SPDT Kontakte

Protoka vode Prekidač Djelomičan Nerđajućeg Čelika Tip 6-380V 1 Vesla Kontrola Protoka Vode Prekidač 1.0 MPa

KM 24.22
Količina robe
Prisutan

OPSEG PRIJAVU : SPDT kontakt vesla tip protok prekidač je iskoristio da izmeri dinamika stanje tekućina prolazi kroz naftovod, poput vode, etilen, glikol i druge tecnosti koje nemaju korozivne efekat na bakar. Molim te provjeri tok prekidač pažljivo prije instalaciju.DOBRA PREDSTAVA : protok kontrolu vrijednost protoka vode prekidač je prilagodljiva, i ponavlja akciju poenta je stabilna. CILJ : protok prekidač je automatska komponenta da kontroliše protok naftovod, i pogodna za vodu tretman sistema, centralna klima uređaj, i vodu za hlađenje opremu.Kada žice, to je potpuno zabranjeno da se prilagodi bilo jebe osim mikro prekidač terminala i kaznio jebe. HFS protok prekidač nije mogla biti korištena u cev koja tečnost temperaturu ispod oslobađajuće trenutku.Oštrica protok prekidač ne može kontakt sa unutrašnje strane cijevi i druge mlaznice u cevi, u suprotnom prekidač ne može resetovati normalno.

Ostale karakteristike

Model:
HFS-25
Voltage:
6-380V
Control mode:
Paddle 
Material:
304 stainless steel body, copper connector,  phosphor bronze bellows
Connector:
1 / 25mm
Max.working pressure:
1.0MPa
Ambient temperature:
0~60℃
Liquid temperature:
-10~100℃(Fluid without icing)
Contact life:
1000000 times
Microswitch Voltage:
220VAC
Microswitch Current:
15A
Weight:
Approx.416g/ 14.7oz
Package List:
1 * Water Flow Switch :
5 * Paddle :
1 * User manual :
Note:
1. Please check the flow switch carefully before installation. :
2. Flow switch can be installed in horizontal pipeline or vertical pipeline with upward liquid flow direction, but not in pipeline with downward liquid flow direction. When installed in the pipeline with upward liquid flow direction, the gravity effect should be considered. :
3. HFS flow switch could not be used in the pipe which liquid temperature below freeing point. :
4. Arrester must be installed if quick-closing valve fixed downstream. :
5. When installing wiring, please pay attention to the following matters:
(1). It is absolutely forbidden to impact the wrench on the switch base plate, which will lead to the deformation and failure of the flow switch. :
(2). When wiring or debugging, cut off the power supply. :
(3). When wiring, it is absolutely forbidden to adjust any screws other than micro switch terminals and grounding screws. And connecting the wire carefully, otherwise it is easy to make the micro switch itself position displacement, resulting in the failure of the flow switch; :
(4). Special grounding screws must be used for wiring, and installation screws cannot be removed. :
(5). The blade of the flow switch cannot contact with the inner wall of the pipe and other throttles in the pipe, otherwise the switch cannot be reset normally. :